Air/water DC inverter controlled heat pump. The outside air is the energy source for this heat pump. This energy is transferred by the heat pump to the water in the heating circuit(s). Thanks to the "Liquid injection technology" it is possible to reach a water temperature of 60°C even at an outside temperature of -20°C. The fan and compressor speeds are modulated according to the heat requirements.
Waterstage Super High Power Fujitsu outdoor unit
- Type WOYG 160 LJL(single-phase)
- Type WOYK 150 LJL (three-phase)
- Type WOYK 170 LJL (three-phase)
Startup
- Startup by CAIROX BELGIUM is highly recommended
Technical data
|
|
Capacity | Heating (-10°C/+35°C)* | kW | 14.8 | 14.05 | 15.04 | Heating (-10°C/+55°C)* | kW | 11.43 | 12.55 | 13.44 | Heating | Nom. capacity (+7°C/+35°C)* | kW | 16 | 15 | 17 | Min - Max capacity (+7°C/+35°C) | kW | (6,59-22,93) | (6,63-22,7) | (6,78-24,27) | Absorbed electric power | kW | 3.86 | 3.46 | 4.1 | COP | | 4.14 | 4.33 | 4.15 | Nom. capacity (+2°C/+35°C)* | kW | 13.3 | 13.2 | 13.5 | Absorbed electric power | kW | 4.25 | 4.06 | 4.27 | COP | | 3.13 | 3.25 | 3.16 | Nom. capacity (+7°C/+55°C)* | kW | 14.5 | 13.2 | 15 | Absorbed electric power | kW | 5.58 | 4.77 | 5.49 | COP | | 2.6 | 2.77 | 2.73 | Liquid injection (compressor) | | Yes | Backup heating resistance | | Yes (2 x 3kW) | Yes (3 x 3kW) | Cooling | | Optional | Seasonal efficiency ηs heat pump | 35°C/55°C | 163/125 | 164/130 | 161/130 | Annual consumption heat pump | kWh 35°C/55°C | 8014/8757 | 8606/9915 | 9059/10232 | Energy class heat pump | 35°C/55°C | A++/A++ | A++/A++ | A++/A++ | Seasonal efficiency ηs DHW | | 109 | 109 | 109 | Annual consumption DHW | kWh | 941 | 941 | 941 | Energy class DHW | | A+ | A+ | A+ | Refrigerant (GWP) | | R410A (2088) | R410A (2088) | R410A (2088) | Indoor unit | Nominal water flow rate | l/min | 57.8 | 54.2 | 61.4 | Minimal water flow rate | l/min | 26.4 | 24 | 27.3 | Max. operational working pressure (heating) | Bar | 3 | Max. operational working pressure (DHW tank) | Bar | 5.5 | Min/Max. water outlet | °C | +8 / +60°C | Water volume | L | 25 | Expansion vessel*** | L | 12 | Sound level @ 1m | dB | 46 | Dimensions (H x W x D) | mm | 1840 x 648 x 698 | Weight | kg | 152 | Volume DHW tank | L | 190 | DHW tank (electrical resistance) | kW | 1.5 | Colour | | White (RAL 9003) | Hydraulic connection diameter | inch | 2 x 1" | Main pipe diameter | inch | 1" | Condensate drain pipe diameter | mm | 32 | Relative humidity limit | % | 15~95 | Type of heat exchanger | | Coaxial heat exchanger | Electrical - hydraulic module | Power supply hydraulic module | V | 230V/1Ph | 400V/3Ph+N | 400V/3Ph+N | Max. absorbed power (backup resistance) | A | 28.2 | 14 | 14 | Automatic fuse (slow) | A | 32 | 20 | 20 | Power supply cable section of backup resistance | mm² | 3G6 | 5G2,5 | 5G2,5 | Section between indoor unit and outdoor unit | mm² | 4G1,5 | 4G1,5 | 4G1,5 | Electrical - DHW | Power supply DHW resistance | V | 230V/1Ph | 230V/1Ph | 230V/1Ph | Max. absorbed power (backup resistance) | A | 7 | 7 | 7 | Automatic fuse (slow) | A | 16 | 16 | 16 | Power supply cable section of backup resistance | mm² | 3G2,5 | 3G2,5 | 3G2,5 | Technical | Refrigerant pipes indoor/outdoor | inch | 3/8 - 5/8 | 3/8 - 5/8 | 3/8 - 5/8 | Stadard prefilled refrigerant | g (CO2eq-T) | 3800 (10,6) | 3800 (10,6) | 3800 (10,6) | Prefilled piping length | m | 15 | 15 | 15 | Additionnal refrigerant R410A | g/m | 50 | 50 | 50 | Min./max. piping length | m | 5/30 | 5/30 | 5/30 | Max. height difference | m | 25/15 | 25/15 | 25/15 | Expansion | | Outdoor unit | Outdor unit | Outdoor unit | * Specifications and design can be modified for further improvement without prior notice | ** Capacities meazsured according to EN14511 measuring method | *** The size of the expansion vessel has to be determined in accordance with the total water volume of the system |
|